Product Details
U-Bend Tube

U-bend tubes are widely used in heat-exchanger systems. Heat-exchanger equipment on the basis of seamless stainless U-tubes is essential in strategically important and critical fields — nuclear and petrochemical machine building.
A tube-bending line, that was installed at our factory in the end of 2005, allows to produce U-tubes
as per such standards:
1. ASTM A688/A688M
2. ASTM A803/A803M
3. ASTM A556/A556M, ASME SA-556
4. ASME SA-179/SA213
Steel Grades:
|
Carbon & Alloy
|
Ferrite
|
Austenite
|
Duplex
|
Super Duplex
|
Ni-alloys
|
Titanium
|
A179 T11 T12 T22
|
TP410
|
TP 304 /
304L TP 316 /
316L TP 316Ti TP 317 /
317L TP 321 TP347
|
S31803 S32205
|
S32750 S32760
|
N06600 N08020 N00880 N08825 N08904
|
Gr.2
|
Tubes of other alloys and steel grades can be produced upon agreement.
Technical requirements
Straight tubes for bending:
ASTM/ASME SA 179; SA 213; ASTM B 163; ASTM B 729; ASTM B 407; ASTM B 423; ASTM A 789
U-bend Tubes:
-TEMA RCB 2.31 Standards of the Tubular Exchanger Manufacturers Association (9th edition).
-ASTM A688 Standard specification for welded tubes of austenite corrosion resistant steel grade designed for feed water boilers.
-ASTM B163 Standard technical requirements for tubes of nickel and nickel alloy for condensers and heat exchangers.
-Customer specifications.
|
u bending
|
BENDING RADIUS: from 1.5 OD to 1250 mm.
When ordering tubes with R≤1.5D it is necessary to agree precision of geometrics.
STRAIGHT TUBES MAXIMUM LENGTH (before bending): 26000 mm.
LEG LENGTH: min 1 meter, max 10.5 meters (for max R=1250 mm)
Note: other sizes are available upon agreement.
HEAT TREATMENT: Stress Relieved after U bending.
HYDROSTATIC TEST: maximum test pressure 600 bar, soaking 10 sec. with demineralized water. Compressed air cleaning after hydro-test.
Marking: before bending by marking machine all over the tube length (bent section after heat treatment without marking).
Marking is also possible after bending on the straight parts of U-bent tube.
Packaging: closed wooden boxes of corresponding dimensions for each tube length, radius, diameter, according to PO requirements or in bundles wrapped in polyethylene film with plastic clamping spacers on each tube.